December 2001 DSP Error Messages NC Software 280 470-xx, 280 472-xx, 280 474-xx 10 5
10.1.2 Axis-Specific DSP Error Messages with Error Code
With the following error messages, in addition to the error code, the number
of the axis or spindle is output:
n y = 0 to 8: Axes 1 to 9
n y = 9 or F: Spindle
Error message Cause of error, corrective action As of
NC SW
DSP ERROR F010 y Motor type unknown, MP2200 (error in motor table or
MP2200)
280 470-01,
280 472-01,
to
280 474-03
DSP ERROR F020 y Reserved
DSP ERROR F030 y Reserved
DSP ERROR F040 y Number of pole pairs too large (error in motor table or
MP2230)
DSP ERROR F050 y ASM: field-defining current (error in motor table)
DSP ERROR F060 y Grating period of velocity encoder (error in motor table)
DSP ERROR F070 y ASM: Rotor time constant (error in motor table)
DSP ERROR F080 y Break/rated speed (error in motor table)
DSP ERROR F090 y Unknown drive type, MP2000
DSP ERROR F0A0 y Reserved
DSP ERROR F0B0 y Reserved
DSP ERROR F0C0 y Reserved
DSP ERROR F0D0 y Current sensor voltage (error in power module table)
DSP ERROR F0E0 y Peak current in power module (error in power module table)
DSP ERROR F0F0 y Current controller proportional factor too high
DSP ERROR F100 y Current controller integral factor too high
DSP ERROR F110 y Motor temperature
DSP ERROR F120 y Reserved
DSP ERROR F130 y Oscilloscope parameter is incorrect. Only for test purposes
(data processing error)
DSP ERROR F140 y Rated current of power module (error in power module)
DSP ERROR F150 y Rated current of motor (error in motor table)
DSP ERROR F160 y Peak current of motor (error in motor table)
DSP ERROR F170 y Max. motor speed (error in motor table)
DSP ERROR F180 y SM: wrong angle compensation values, MP2340, MP2350
DSP ERROR F190 y Power module dc-link voltage incorrect
DSP ERROR F1A0 y Invalid rotational speed input selected
DSP ERROR F1B0 y Invalid PWM output
DSP ERROR F1C0 y Band-pass parameter incorrect, MP2540, MP2550
DSP ERROR F200 y Contamination of encoder Zn track, amplitude too small
DSP ERROR F210 y Contamination of encoder Z1 track, amplitude too small
DSP ERROR F220 y Reserved
DSP ERROR F230 y Motor temperature too high
DSP ERROR F240 y Unknown counter chip type at rotational speed input
(hardware problem)

Table of Contents