EasyManua.ls Logo

HEIDENHAIN TNC 430 PA/M - RS-422;V.11 Data Interface

HEIDENHAIN TNC 430 PA/M
1135 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
December 2001 Data Interface 3 61
3.10.2 RS-422/V.11 Data Interface
Please note:
n Maximum cable length 1000 m.
n To connect a peripheral device you must install an adapter cable either in the
electrical cabinet or on the operating panel. See also Dimensions at the
end of this chapter.
n For connecting cables, see Cable Overview at the end of this chapter.
X22: RS-422/V.11
data interface
Pin layouts on logic unit, connecting cables, and adapter block:
Logic unit Connecting cable Id. Nr. 289 208-xx PL Id. Nr. 310 086-01
D-sub
cnnctr.
(female)
15-pin
Assignment D-sub
connctr.
(male)
15-pin
D-sub
cnnctr.
(female)
15-pin
D-sub
connctn.
(male)
15-pin
D-sub
cnnctr.
(female)
15-pin
1 Chassis GND 1 black external shield 1 1 1
2RXD 2Blue 222
3CTS 3Gray 333
4TXD 4White 444
5 RTS 5 Green 5 5 5
6DSR 6White/Green 666
7 DTR 7 Green/Pink 7 7 7
8 Signal GND 8 Black 8 8 8
9RXD
9Red 999
10 CTS
10 Pink 10 10 10
11 TXD 11 Brown 11 11 11
12 RTS
12 Yellow 12 12 12
13 DSR
13 Brown/Green 13 13 13
14 DTR 14 Red/Blue 14 14 14
15 Do not assign 15 Violet 15 15 15
Housing External shield Housing External shield Housing Housing Housing

Table of Contents

Related product manuals