December 2001 List of Machine Parameters 4 – 39
4.3.9 3-D touch probe
MP Function and input Software
version and
behavior
Page
MP6010 Selection of the touch probe
Input: 0: Touch probe with cable transmission
1: Touch probe with infrared transmission
PLC, CN123 6 – 346
MP6120 Probing feed rate (triggering touch probe)
Input: 1 to 3000 [mm/min]
PLC, CN123
RUN
6 – 349
MP6130 Maximum measuring range
Input: 0.001 to 99 999.9999 [mm]
PLC, CN123
RUN
6 – 349
MP6140 Setup clearance over measuring point
Input: 0.001 to 99 999.9999 [mm]
PLC, CN123
RUN
6 – 349
MP6150 Rapid traverse in probing cycle (triggering touch probe)
Input: 10 to 20 000 [mm/min]
PLC, CN123
RUN
6 – 349
MP6160 M function for probing from opposite directions
Input: -1: Spindle orientation directly by NC
0: Function inactive
1 to 999: Number of the M function for
spindle orientation by the PLC
PLC, CN123
RUN
6 – 352
MP6161 M function for orienting the touch probe before every
measuring process
Input: -1: Spindle orientation directly by the NC
0: Function inactive
1 to 999: Number of the M function
280 474-08
PLC, CN123
RUN
6 – 350
MP6162 Orientation angle
Input: 0 to 359.9999 [°]
280 474-08
PLC, CN123
RUN
6 – 350
MP6163 Minimum difference between the current spindle angle and
MP6162 before executing an oriented spindle stop
Input: 0 to 3.0000 [°]
280 474-08
PLC, CN123
RUN
6 – 350
MP6165 Orient the probe before approaching with Cycle 0 or 1, or
with manual probing
Input: 0: Probe is not oriented before each probing
1: Probe is oriented and always
deflected in the same direction
280 476-10
PLC, CN123
RUN
6 – 350
MP6170 Number of measurements in a programmed measurement
(touch probe block)
Input: 1 to 3
PLC, CN123
RUN
6 – 353