6 346 HEIDENHAIN Technical Manual TNC 426, TNC 430
6.15 Touch Probe
The following touch probes can be connected:
n Touch trigger probes
TS 120, TS 220: With cable connection for digitizing, tool setup and
measuring during machining
TS 632: With infrared transmission for workpiece setup and
measurement during machining
TT 130: For tool measurement
n Measuring touch probe
For connecting the touch probes: (See "Mounting and Electrical Installation
on page 3 5).
7
77
7 With MP6010 and MP6200, specify which touch probes are connected.
7
77
7 Make sure that the spindle is locked during the measuring process.
With FN18 you can read the current touch probe data.
MP6010 Selection of the touch probe
Input: 0: Touch probe with cable transmission
1: Touch probe with infrared transmission
MP6200 Selection of triggering or measuring touch probe (only with
digitizing with measuring touch probe option)
Input: 0: Triggering touch probe (e.g. TS 220)
1: Measuring touch probe
Module 9135 Switch on 3-D touch probe
With Module 9135 you can switch on or retrigger certain 3-D touch probes. If
the touch probe is already switched on, the module call has no effect. If
M4056 is set and the touch probe does not provide a ready signal, the feed-
rate enabling (M4563) is reset.
Call:
CM 9135
Error recognition:
Note
The TNC 426/430 always emits a start signal when beginning a touch probe
cycle, meaning Module 9135 does not need to be used for HEIDENHAIN
touch probes.
Marker Value Meaning
M4203 0 No error
1 Error in module run