December 2001 Display and Operation 6 – 241
Clearing the status
display
To erase the status display, tool data and contents of the Q parameters:
7
77
7 Select the conditions with MP7300. All programmed values in the status
display, such as scaling factor, datum shift, and feed rate are reset. The
Q parameters and tool data are set to zero.
MP7300 Erasing the status display and Q parameters
Input: 0: Erase the status display, Q parameters and tool data when a
program is selected.
1: Erase the status display, Q parameters and tool data if a
program is selected and M02, M30, and END PGM occur.
2: Erase the status display and tool data when a program is
selected.
3: Erase the status display and tool data when a program is
selected and in the event of M02, M30, END PGM.
4: Erase the status display and Q parameters when a program
is selected.
5: Erase the status display and Q parameters when a program
is selected and in the event of M02, M30, END PGM.
6: Erase the status display when a program is selected and in
the event of M02, M30, END PGM.
7: Erase the status display when a program is selected and in
the event of M02, M30, END PGM.
Input Erase with
PGM MGT
Erase with
M02, M30,
END PGM
Status
display
Tool data Q para-
meters
0x– xx x
1xx xx x
2x– xx –
3xx xx –
4x– x – x
5xx x– x
6x– x ––
7xx x––