EasyManua.ls Logo

HEIDENHAIN TNC 430 PA/M - Connecting the Motor Power Module

HEIDENHAIN TNC 430 PA/M
1135 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
3 44 HEIDENHAIN Technical Manual TNC 426, TNC 430
3.6 Connecting the Motor Power Module
The LE 426 M and the LE 430 M can be operated with HEIDENHAIN and with
non-HEIDENHAIN inverter systems. The LE 426 PB and the LE 430 PA can
only be operated with non-HEIDENHAIN inverter systems.
For a description of the HEIDENHAIN inverter systems, refer to the Technical
Manual Inverter Systems and Motors. The components required for
operation of the LE with non-HEIDENHAIN inverter systems are described in
the manual Technical Information for the Operation of SIMODRIVE and
POWER DRIVE Inverter Systems.
X51 to X59, X61:
Outputs to the
motor power
module
The following applies for the outputs to the motor power module:
Logic level: 5 V
Analog signals I
ACT
: ±7.5 V
PWM frequency X51 to X59: Can be set from 3 kHz to 7 kHz via MP2180
PWM frequency X61: 5 kHz
Output Speed
X51 to X59 Axis 1 to 9,
or spindle (TNC 426 PB/M with 12 000 rpm)
X61 Spindle (TNC 430 PA/M and TNC 426 PB/M with 30 000 rpm)

Table of Contents