December 2001 Touch Probe 6 349
Probing from OEM
cycles
7
77
7 With FN17:SYSWRITE ID990 NR1, adjust the approach behavior. If the input
value = 0, the setup clearance from MP6140 and the effective radius are
accounted for. If the input value > 0, the workpiece is approached as if the
effective radius and setup clearance were zero. This function can be used,
for example, for measuring small holes.
If you use the TS 632 infrared touch probe, you must orient the touch probe
before the measuring process in order to align the touch probe and the
receiver unit. Define an M function for automatically orienting the probe to a
specific position before probing. If the ready signal of the touch probe is
already available, the touch probe is not oriented.
7
77
7 In MP6161, enter the number of the M function.
7
77
7 Enter the orientation angle in MP6162.
7
77
7 In MP6163, enter a minimum angle difference for orienting with the defined
M function.
MP6120 Probing feed rate (triggering touch probe)
Input: 1 to 3000 [mm/min]
MP6360 Probing feed rate (measuring touch probe)
Input: 1 to 3000 [mm/min]
MP6130 Maximum measuring range
Input: 0.001 to 99 999.9999 [mm]
MP6140 Setup clearance over measuring point
Input: 0.001 to 99 999.9999 [mm]
MP6150 Rapid traverse in probing cycle (triggering touch probe)
Input: 10 to 20 000 [mm/min]
Set Reset
M4050 Touch probe not ready, ready signal
is missing
NC NC
M4051 Stylus deflected before start of
probing cycle
NC NC
M4052 Stylus is deflected, probing process
is completed
NC PLC
M4053 Probing process has been ended or
canceled
NC NC
M4054 Battery voltage too low (battery
warning at touch probe connection);
evaluated only during the probing
process
NC NC
M4055 Enable the probing process NC PLC
M4056 NC stop in all operating modes if
stylus is deflected
PLC PLC
M4574 Select the traverse range (with
M4575)
PLC PLC
M4575 Select the traverse range (with
M4574)
PLC PLC
Orient when MP6163 < current spindle angle MP6162()