3 28 HEIDENHAIN Technical Manual TNC 426, TNC 430
3.4.5 Power Supply for the PL 4xxB
X9 to X14:
Power supply
Pin layout on the PL 410B:
Pin layout on the PL 405B:
X23: Power supply
for the analog
inputs on the
PL 410B
The PL 410B input/output unit is also available with additional analog inputs
and inputs for Pt 100 thermistors. The power supply must comply with
EN 50 178, 5.88 requirements for low voltage electrical separation.
Terminal Assignment PL 1 PL 2 PL 3 PL 5
X9 0 V
X10 +24 Vdc logic power supply and for control-is-ready signal
X11 +24 Vdc
Power
supply for
outputs
O32 O39 O64 O71 O128
O135
O160
O167
X12 +24 Vdc
Power
supply for
outputs
O40 O47 O72 O79 O136
O143
O168
O175
X13 +24 Vdc
Power
supply for
outputs
O48 O55 O80 O87 O144
O151
O176
O183
X14 +24 Vdc
Power
supply for
outputs
O56 O62 O88 O94 O152
O158
O184
O190
Terminal Assignment PL 1 PL 2 PL 3 PL 4
X9 0 V
X10 +24 Vdc logic power supply and for control-is-ready signal
X13 +24 Vdc
Power
supply for
outputs
O48 O55 O80 O87 O144
O151
O176
O183
X14 +24 Vdc
Power
supply for
outputs
O56 O62 O88 O94 O152
O158
O184
O190
Terminal Assignment
1 +24 Vdc as per EN 50 178, 5.88
2+0 V