December 2001 Commissioning 6 – 499
11. Check the acceleration feedforward:
7
77
7 Select operation with velocity feedforward control
7
77
7 Enter the following test program:
LBL 1
L X+100 R0 F5000
L X-100 R0 F5000
CALL LBL 1/10
7
77
7 Use the integrated oscilloscope to record the actual shaft speed
(ACTUAL RPM), the nominal current value (I NOMINAL), and the integral-
action component of the nominal current value I (INT RPM).
7
77
7 Start the test program.
7
77
7 Adjust the speed with the feed rate override knob so that I NOMINAL is not
limited.
7
77
7 Measure the gradient of the acceleration ramp in the part in which
I (INT RPM) remains constant.
7
77
7 Calculate MP2600.x:
I (INT RPM) = Integral-action component of the nominal current value
t = Acceleration time in which I (INT RPM) remains constant
∆V (ACT RPM) = Change of actual rpm during t
MP2020.x = Traverse distance per motor revolution
7
77
7 Repeat this measurement to check the input value of MP2600.x.
I (INT RPM) must have approached zero.
MP2600.x
I (N INT) [A] t [s] 60 [s/min] MP2020.x [mm]⋅⋅ ⋅
∆V(N IST) [mm/min]
----------------------------------------------------------------------------------------------------------------------------=