EasyManua.ls Logo

HEIDENHAIN TNC 430 PA/M - Module 9125 Stop PLC Axis at Next Hirth Grid Position

HEIDENHAIN TNC 430 PA/M
1135 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
6 32 HEIDENHAIN Technical Manual TNC 426, TNC 430
Module 9125 Stop PLC axis at next Hirth grid position
Stop an already started PLC-positioning of an axis at the next Hirth grid
position.
Call:
PS B/W/D/K <Axis>
0 to 8 correspond to axes 1 to 9
CM 9125
PL B/W/D <Error code>
0: Positioning is canceled
1: Axis does not exist
2: Not a PLC axis
3: Axis was already stationary
4: Axis is not a Hirth axis (MP420.x)

Table of Contents