4 – 40 HEIDENHAIN Technical Manual TNC 426, TNC 430
MP6171 Confidence range for programmed measurement
(MP6170 > 1)
Input: 0.002 to 0.999 [mm]
PLC, CN123
RUN
6 – 353
MP6180 Coordinates of the ring gauge center for Probing Cycle 2
with respect to the machine datum (traverse range 1)
Input: 0 to +99 999.9999 [mm]
280 472-05
PLC, CN123
6 – 352
MP6180.0 X coordinate
MP6180.1 Y coordinate
MP6180.2 Z coordinate
MP6181 Coordinates of the ring gauge center for Probing Cycle 2
with respect to the machine datum (traverse range 2)
Input: 0 to +99 999.9999 [mm]
280 472-05
PLC, CN123
6 – 352
MP6181.0 X coordinate
MP6181.1 Y coordinate
MP6181.2 Z coordinate
MP6182 Coordinates of the ring gauge center for Probing Cycle 2
with respect to the machine datum (traverse range 3)
Input: 0 to +99 999.9999 [mm]
280 472-05
PLC, CN123
6 – 353
MP6182.0 X coordinate
MP6182.1 Y coordinate
MP6182.2 Z coordinate
MP6185 Distance of probing point below ring top surface during
calibration
Input: +0.001 to +99 999.9999 [mm]
280 472-05
PLC, CN123
6 – 353
MP Function and input Software
version and
behavior
Page