December 2001 Tilting Axes 6 73
MP 7510.0 : %000001
;X coordinate of the center of rotation of axis C
MP 7510.1 : %000010
;Y coordinate of the center of rotation of axis C
MP 7510.2 : %000100
;Z coordinate of the center of rotation of axis C
MP 7510.3 : %100000 ;Free tilting axis C
MP 7510.4 : %000010 ;Shift in Y axis (Y1)
MP 7510.5 : %000100 ;Shift in Z axis (Z1)
MP 7510.6 : %001000 ;Free tilting axis A
MP 7510.7 : %000100 ;Shift in Z axis (Z2)
MP 7510.8 : %010000 ;Free tilting axis B
MP 7510.9 : %000000 ;End of the transformation chain
MP 7520.0 : %11 ;Absolute dimension, tilting table
MP 7520.1 : %11 ;Absolute dimension, tilting table
MP 7520.2 : %11 ;Absolute dimension, tilting table
MP 7520.3 : %01 ;Tilting table
MP 7520.4 : %01 ;Tilting table
MP 7520.5 : %01 ;Tilting table
MP 7520.6 : %01 ;Tilting table
MP 7520.7 : %01 ;Tilting table
MP 7520.8 : %01 ;Tilting table
MP 7530.0 : +420 ;Dimension XR
MP 7530.1 : +151.2 ;Dimension YR
MP 7530.2 : -395.4 ;Dimension ZR
MP 7530.3 : +0 ;Variable dimension (free tilting axis C)
MP 7530.4 : -2.7 ;Dimension Y1
MP 7530.5 : 331.3 ;Dimension Z1
MP 7530.6 : +0 ;Variable dimension (free tilting axis A)
MP 7530.7 : +125.9 ;Dimension Z2
MP 7530.8 : +0 ;Variable dimension (free tilting axis B)