December 2001 Display and Operation 6 – 251
Module 9080 Clearing the small PLC window
With this module you can clear the contents of the small PLC window.
The background color is defined in MP7320.2 and MP7356.0.
Call:
CM 9080
Error recognition:
Module 9081 Interrogating the status of the small PLC window
With this module you can ascertain whether a small PLC window is being
displayed.
Call:
CM 9081
PL B/W/D <Status of the small PLC window>
Bit 0 = 1: A small window is in the selected screen
(background or foreground)
Bit 1 = 1: Small PLC window in the foreground
Marker Value Meaning
M4203 0 No error
1 Call was not in a submit or spawn job