101
────────────────────────────────────────────────────
8.3.3 Specific Commands for Output Settings
────────────────────────────────────────────────────
Syntax
:OUT? <ch>
<ch> Channel number
= 1 to 4 (1 to 2 for the 7075-01)
Response
syntax
(Header ON)
:OUT <ch>,<ON/OFF>
(Header OFF)
<ch>,<ON/OFF>
Example
Transmission
Response
:OUT? 1
(Header ON)
:OUT 1,ON
(Header OFF)
1,ON
Syntax
:RUN
Example
Transmission
:RUN
Syntax
:RUN?
Response
syntax
(Header ON)
:RUN <0/1>
(Header OFF)
<0/1>
Example
Transmission
Response
:RUN?
(Header ON)
:RUN 1
(Header OFF)
1
Function
Returns the relay setting for the
specified channel as a character data.
Note
With this query, if any error occurs, no
response message is produced.
Function
Starts output.
Note
Output cannot be started during a
system memory test.
Error
(Execution error)
During a system memory test.
Function
Returns the output setting as NR1
numerical data.
0: stop
1: output
Note
With this query, if any error occurs, no
response message is produced.
:OUT?
Queries the output relay setting.
:RUN
Starts output.
:RUN?
Query the output status