117
────────────────────────────────────────────────────
8.3.6 Specific Commands for Others
────────────────────────────────────────────────────
Syntax
:COM:TERMinator?
Response
syntax
(Header ON)
:COM:TERM <0/1/2>
(Header OFF)
<0/1/2>
Example
Transmission
Response
:COM:TERM?
(Header ON)
:COM:TERM 1
(Header OFF)
1
Syntax
:COM:ERRor <ON/OFF>
Example
Transmission
:COM:ERROR ON
Displays the command error display.
Syntax
:COM:ERRor?
Response
syntax
(Header ON)
:COM:ERROR <ON/OFF>
(Header OFF)
<ON/OFF>
Example
Transmission
Response
:COM:ERROR?
(Header ON)
:COM:ERROR ON
(Header OFF)
ON
Function
Returns the current setting of
terminator as NR1 numerical data.
Note
With this query, if any error occurs, no
response message is produced.
Function
Enables or disables the command error
display of the RS-232C interface.
Error
(Command error)
When the character data other than ON
or OFF is set.
Function
Returns the current setting of
command error display as character
data (ON/OFF).
:COM:TERMinator? (RS-232C only)
Queries the response message terminator setting.
:COM:ERRor (RS-232C only)
Sets the command error display.
:COM:ERRor? (RS-232C only)
Queries the command error display setting.