supply (DBPS) for the small/
large form factor drive trays.
af50xx Check the connection of the
power cables on the power
supply (DBPS) for the flash
module drive tray.
Replacing a power supply on
page 141
fffa0x Check the connection of the
batteries on the backup
module (BKMF).
Replacing a backup module
on page 269
aff1xx Troubleshoot the GUM failure. Troubleshooting the
maintenance utility on
page 338
af4a0x Check power supply
(CHBBPS) connections.
Checking power cable
connections on a host port
expansion chassis on
page 157
af4b0x Check the connection of the
CHBBPS power cables to the
CHBB power supply unit.
Checking power cable
connections on a host port
expansion chassis on
page 157
af4cxx Check that the screw is
secure on the CHBBFAN fan.
Checking the screw on a host
port expansion chassis fan on
page 137
Reference codes other than
those above
Contact the HDS Support Portal at https://support.hds.com/
en_us/contact-us.html.
8. Click Action Code to check the replacement procedure.
9. Read the recovery steps shown in the Recovery Procedure window.
The following window shows an example of a drive failure.
Verifying component failures 29
Service Guide for VSP Gx00 and VSP Fx00 Models