269
<Description hp:regExp="[A-Z]*"/>
</Interface>
</Interfaces>
</Ifmgr>
</top>
</filter>
</get-config>
</rpc>
• Conditional match
To implement a complex data filtering with digits and character strings, you can add a match
attribute for a specific element. Table 38 lists the conditional match operators.
Table 38 Conditional match operators
Operation
Operator
Remarks
More than match="more:value"
More than the specified value
. The supported data types
include date, digit, and character string.
Less than match="less:value"
Less than the specified value. The supported data types
include date, digit, and character string.
Not less than match="notLess:value"
Not less than the specified value. The supported data types
include date, digit, and character string.
Not more than match="notMore:value"
Not more than the specified value. The supported data types
include date, digit, and character string.
Equal match="equal:value"
Equal to the specified value. The supported data types include
date, digit, character string, OID, and BOOL.
Not equal match="notEqual:value"
Not equal to the specified value. The supported data types
include date, digit, character string, OID, and BOOL.
Include match="include:string"
Includes the specified string. The supported data types include
only character string.
Not include match="exclude:string"
Excludes the specified string. The supported data types include
only character string.
Start with match="startWith:string"
Starts with the specified string. The supported data types
include character string and OID.
End with match="endWith:string"
Ends with the specified string.
The supported data types
include only character string.
# Copy the following text to the client to retrieve extension information about the entity of which
the CPU usage is more than 50%:
<rpc message-id="100" xmlns="urn:ietf:params:xml:ns:netconf:base:1.0"
xmlns:hp="http://www.hp.com/netconf/base:1.0">
<get>
<filter type="subtree">
<top xmlns="http://www.hp.com/netconf/data:1.0">
<Device>
<ExtPhysicalEntities>
<Entity>
<CpuUsage hp:match="more:50"></CpuUsage>
</Entity>
</ExtPhysicalEntities>
</Device>

Table of Contents

Other manuals for HPE FlexNetwork 5510 HI Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HPE FlexNetwork 5510 HI Series and is the answer not in the manual?

HPE FlexNetwork 5510 HI Series Specifications

General IconGeneral
BrandHPE
ModelFlexNetwork 5510 HI Series
CategorySwitch
LanguageEnglish

Related product manuals