<Sysname> system-view
[Sysname] poe-profile abc
[Sysname-poe-profile-abc-1] poe priority critical
[Sysname-poe-profile-abc-1] quit
[Sysname] interface gigabitEthernet 1/0/1
[Sysname-GigabitEthernet1/0/1] apply poe-profile name abc
Related commands
poe pd-policy priority
poe priority (system view)
Use poe priority to set the power supply priority for a PSE.
Use undo poe priority to restore the default.
Syntax
poe priority { critical | high | low } pse pse-id
undo poe priority pse pse-id
Default
The power supply priority of a PSE is low.
Views
System view
Predefined user roles
network-admin
Parameters
critical: Sets the power supply priority to critical. The PSE with critical power priority operates in
guaranteed mode, and power is supplied to it first.
high: Sets the power supply priority to high.
low: Sets the power supply priority to low.
pse pse-id: Specifies a PSE by its ID.
Usage guidelines
If PSE power management is disabled, the system does not supply power to new PSEs when PoE
power overload occurs.
If PSE power management is enabled, when PSE power overload occurs, the system supplies
power to a PSE with higher priority. For multiple PSEs with the same priority, the PSE with a smaller
ID gets power supplied first.
For example, if PoE is enabled for a PSE, and the PSE has higher priority, the system performs the
following operations:
• Stops supplying power to a PSE with lower priority.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HPE FlexNetwork MSR3044 and is the answer not in the manual?

HPE FlexNetwork MSR3044 Specifications

General IconGeneral
BrandHPE
ModelFlexNetwork MSR3044
CategoryNetwork Router
LanguageEnglish

Related product manuals