80
statistics interval
Use statistics interval to set the statistics collection interval for an NQA operation.
Use undo statistics interval to restore the default.
Syntax
statistics interval interval
undo statistics interval
Default
The statistics collection interval is 60 minutes.
Views
DHCP/DLSw/DNS/FTP/HTTP/SNMP/TCP/voice operation view
ICMP/UDP echo operation view
ICMP/path/UDP jitter operation view
Predefined user roles
network-admin
Parameters
interval: Specifies the interval in minutes, in the range of 1 to 35791394.
Usage guidelines
NQA forms statistics within the same collection interval as a statistics group. To display information
about the statistics groups, use the display nqa statistics command.
Examples
# Configure NQA to collect the ICMP echo operation statistics every 2 minutes.
<Sysname> system-view
[Sysname] nqa entry admin test
[Sysname-nqa-admin-test] type icmp-echo
[Sysname-nqa-admin-test-icmp-echo] statistics interval 2
statistics max-group
Use statistics max-group to set the maximum number of statistics groups that can be saved.
Use undo statistics max-group to restore the default.
Syntax
statistics max-group number
undo statistics max-group

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HPE FlexNetwork MSR3044 and is the answer not in the manual?

HPE FlexNetwork MSR3044 Specifications

General IconGeneral
BrandHPE
ModelFlexNetwork MSR3044
CategoryNetwork Router
LanguageEnglish

Related product manuals