huawei(config-if-gpon-0/1)#if-h248 add 0 1 1 mgc-profile profile-id 2
huawei(config-if-gpon-0/1)#if-h248 add 0 2 1 mgc-profile profile-id 2
2. Add POTS users.
For ONU 1 and ONU 2, create a POTS user, set the MG ID to 1 (identical to the MG ID
of the H.248 interface), and set the physical terminal port ID to A0 and A1.
huawei(config-if-gpon-0/1)#mgpstnuser add 0 1 1 mgid 1 terminalid A0
huawei(config-if-gpon-0/1)#mgpstnuser add 0 2 1 mgid 1 terminalid A1
Run the display mgpstnuser attribute command to check whether the configuration of
the POTS user is properly set.
huawei(config-if-gpon-0/1)#display mgpstnuser attribute 0 1 1
------------------------------------------------------------------------------
F/S/P : 0/1/0
ONT ID : 1
Port ID : 1
MG ID : 1
Terminal ID : A0
...//The rest of the response information is omitted.
huawei(config-if-gpon-0/1)#display mgpstnuser attribute 0 2 1
------------------------------------------------------------------------------
F/S/P : 0/1/0
ONT ID : 2
Port ID : 1
MG ID : 1
Terminal ID : A1
...//The rest of the response information is omitted.
Step 6 Apply ONU voice service profiles
After ONU voice service profiles are applied, if parameters in those profiles are changed, those
profiles must be reapplied so that the changed parameters can take effect.
1. Apply an interface common profile.
Run the if-h248 attribute command to apply an interface common profile to an H.248
interface or configure the interface customized parameters, or run the ont-if-h248 bat-
apply command to bulk apply the interface common profiles to H.248 interfaces. If you
use these two commands to apply the interface common profiles or configure the interface
customized parameters repeatedly, the last configurations take effect.
In this example, the default interface common profile, namely interface common profile 1
is used.
2. Apply a POTS port profile.
Run the pstnport electric command to apply a POTS port profile to an H.248 interface or
configure the interface customized parameters, or run the ont-pstnport electric bat-
apply command to bulk apply the POTS port profiles to H.248 interfaces. If you use these
two commands to apply the POTS port profiles or configure the interface customized
parameters repeatedly, the last configurations take effect.
In this example, the default POTS port profile, namely POTS port profile 1 is used.
Step 7 (Optional) Configure the H.248 user codec.
Run the mgpstnuser codec command to configure the H.248 user codec. The H.248 user codec
will not be configured independently in this example.
SmartAX MA5600T/MA5603T/MA5608T Multi-service
Access Module
Commissioning and Configuration Guide
12 FTTO Configuration(SOHO and SME)
Issue 01 (2014-04-30) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
1118

Table of Contents

Other manuals for Huawei SmartAX MA5608T

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Huawei SmartAX MA5608T and is the answer not in the manual?

Huawei SmartAX MA5608T Specifications

General IconGeneral
Dual Power SupplyYes
Humidity5% to 95% (non-condensing)
Uplink Slots2
Maximum GPON Ports16
Input Voltage Range-38.4 V DC to -72 V DC
Device TypeOLT
Power Supply-48 V DC
Operating Temperature-25°C to +55°C
Storage Temperature-40°C to 70°C
Switching Capacity128 Gbps
PortsGPON, XG-PON, 10GE