EasyManuals Logo

Huawei SmartAX MA5608T User Manual

Huawei SmartAX MA5608T
1979 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #722 background imageLoading...
Page #722 background image
In this example, the default SIP service data profile, namely SIP service data profile 1 is
used.
3. Apply a POTS port profile.
Run the pstnport electric command to apply a POTS port profile to an SIP interface or
configure the interface customized parameters, or run the ont-pstnport electric bat-
apply command to bulk apply the POTS port profiles to SIP interfaces. If you use these
two commands to apply the POTS port profiles or configure the interface customized
parameters repeatedly, the last configurations take effect.
In this example, the default POTS port profile, namely POTS port profile 1 is used.
4. Bind a digitmap profile.
Run the sippstnuser digitmap command to bind a digitmap profile to an SIP interface, or
run the ont-sippstnuser bat-bind from command to bulk apply the digitmap profiles to
SIP interfaces. If you use these two commands to bind the SIP service data profiles to SIP
ports repeatedly, the last configurations take effect.
In this example, the default digitmap profile, namely digitmap profile 1 is used.
Step 10 (Optional) Configure the SIP user codec.
Run the sippstnuser codec command to configure the SIP user codec. The SIP user codec will
not be configured independently in this example.
Step 11 Save the data.
huawei(config)#save
----End
9.7.3.9 Configuring the BTV Service
The OLT is connected to the remote gateway ONT through a GPON port to provide users with
the bridge WAN multicast service.
Prerequisites
l The iTMS has configured the IPTV WAN ports on the ONT.
l The OLT has been connected to the BRAS and the multicast source.
l The VLAN of the LAN switch port connected to the OLT is the same as the upstream
VLAN of the OLT.
l The ONT has been added to the OLT. For details, see 9.7.1.3 Adding an ONT to an
OLT.
Data Plan
Table 9-6 Data plan
Item Data
ONT line profile Profile name: ftth
T-CONT ID: 4
GEM port ID: 13
SmartAX MA5600T/MA5603T/MA5608T Multi-service
Access Module
Commissioning and Configuration Guide 9 FTTH Configuration
Issue 01 (2014-04-30) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
697

Table of Contents

Other manuals for Huawei SmartAX MA5608T

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Huawei SmartAX MA5608T and is the answer not in the manual?

Huawei SmartAX MA5608T Specifications

General IconGeneral
Dual Power SupplyYes
Humidity5% to 95% (non-condensing)
Uplink Slots2
Maximum GPON Ports16
Input Voltage Range-38.4 V DC to -72 V DC
Device TypeOLT
Power Supply-48 V DC
Operating Temperature-25°C to +55°C
Storage Temperature-40°C to 70°C
Switching Capacity128 Gbps
PortsGPON, XG-PON, 10GE

Related product manuals