Parameter Value
Bearing
service
OTHER: The connection is used for the BTV service.
VLAN
enabling
Enable VLAN tags are added to upstream packets.
NOTE
When BTV service flows are created on the OLT, the value is
Disable if uservlan is untagged and the value is Enable if
uservlan is tagged.
VLANID
[1-4094]
VLAN ID corresponding to the user VLAN value for BTV
service flows created on the OLT. In this example, set this
parameter to 43.
Binding item LAN3
Mode Bridge
DHCP
transparent
transmission
Enable
c. Click OK to save the settings.
3. Restart the HGW.
Choose Management > Device Management and click Restarting the Device.
----End
9.7.2.7 Configuring the VoD Service
The OLT is connected to the remote bridging ONT through a GPON port to provide users with
the VoD service.
Prerequisites
l The OLT is connected to the BRAS and the program source.
l The VLAN of the LAN switch port connected to the OLT is the same as the upstream
VLAN of the OLT.
l The ONT has been added to the OLT. For details, see 9.7.1.3 Adding an ONT to an
OLT.
l The configuration processes on HGWs of different models or in different appearances are
similar. This topic describes how to configure the Internet access service on an HG239 that
is connected to an ONT upstream through a LAN.
SmartAX MA5600T/MA5603T/MA5608T Multi-service
Access Module
Commissioning and Configuration Guide
9 FTTH Configuration
Issue 01 (2014-04-30) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
645

Table of Contents

Other manuals for Huawei SmartAX MA5608T

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Huawei SmartAX MA5608T and is the answer not in the manual?

Huawei SmartAX MA5608T Specifications

General IconGeneral
Dual Power SupplyYes
Humidity5% to 95% (non-condensing)
Uplink Slots2
Maximum GPON Ports16
Input Voltage Range-38.4 V DC to -72 V DC
Device TypeOLT
Power Supply-48 V DC
Operating Temperature-25°C to +55°C
Storage Temperature-40°C to 70°C
Switching Capacity128 Gbps
PortsGPON, XG-PON, 10GE