huawei(config)#interface gpon 0/1
huawei(config-if-gpon-0/1)#ont ipconfig 0 1 dhcp vlan 20
huawei(config-if-gpon-0/1)#ont ipconfig 0 2 dhcp vlan 20
Step 5 Configure H.248 POTS users.
1. Add an H.248 interface and apply an MGC interface profile to the interface.
For ONU 1 and ONU 2, set the MG ID to 1, apply MGC interface profile 2 to ONU 1 and
ONU 2, and use default values for other parameters.
If parameters of an MGC interface profile are changed, the MGC interface profile must be
reapplied to the ONU so that the changed parameters can take effect.
huawei(config-if-gpon-0/1)#if-h248 add 0 1 1 mgc-profile profile-id 2
huawei(config-if-gpon-0/1)#if-h248 add 0 2 1 mgc-profile profile-id 2
2. Add POTS users.
For ONU 1 and ONU 2, create a POTS user, set the MG ID to 1 (identical to the MG ID
of the H.248 interface), and set the physical terminal port ID to A0 and A1.
huawei(config-if-gpon-0/1)#mgpstnuser add 0 1 1 mgid 1 terminalid A0
huawei(config-if-gpon-0/1)#mgpstnuser add 0 2 1 mgid 1 terminalid A1
Run the display mgpstnuser attribute command to check whether the configuration of
the POTS user is properly set.
huawei(config-if-gpon-0/1)#display mgpstnuser attribute 0 1 1
------------------------------------------------------------------------------
F/S/P : 0/1/0
ONT ID : 1
Port ID : 1
MG ID : 1
Terminal ID : A0
...//The rest of the response information is omitted.
huawei(config-if-gpon-0/1)#display mgpstnuser attribute 0 2 1
------------------------------------------------------------------------------
F/S/P : 0/1/0
ONT ID : 2
Port ID : 1
MG ID : 1
Terminal ID : A1
...//The rest of the response information is omitted.
Step 6 Apply ONU voice service profiles
After ONU voice service profiles are applied, if parameters in those profiles are changed, those
profiles must be reapplied so that the changed parameters can take effect.
1. Apply an interface common profile.
Run the if-h248 attribute command to apply an interface common profile to an H.248
interface or configure the interface customized parameters, or run the ont-if-h248 bat-
apply command to bulk apply the interface common profiles to H.248 interfaces. If you
use these two commands to apply the interface common profiles or configure the interface
customized parameters repeatedly, the last configurations take effect.
In this example, the default interface common profile, namely interface common profile 1
is used.
2. Apply a POTS port profile.
SmartAX MA5600T/MA5603T/MA5608T Multi-service
Access Module
Commissioning and Configuration Guide
12 FTTO Configuration(SOHO and SME)
Issue 01 (2014-04-30) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
1208