EasyManuals Logo

Huawei SmartAX MA5608T User Manual

Huawei SmartAX MA5608T
1979 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #1404 background imageLoading...
Page #1404 background image
Synchronization
Solution
Usage Scenario Advantage Limitation or
Hardware
Requirements
E1/STM-1/T1 line
clock
Applies to the BTS
that requires only
frequency
synchronization,
such as GSM/
WCDMA. In
addition, the OLT
can directly connect
to an SDH network.
1. Clock precision
meets the
following
requirements:
l G.8262
features when
CKMC/
CKMD
stratum-3
clock units are
configured
l EEC
specifications
defined in G.
8261 when no
stratum-3
clock units are
configured
2. E1/STM-1 line
clocks are all
obtained from
physical line
clocks and they
have the best
performance in
terms of stability
and reliability.
1. In E1/STM-1
upstream
transmission, the
OLT must be in
the same office as
SDH equipment.
2. E1/STM-1 line
clocks support
only frequency
synchronization.
Boards that support
this feature:
l STM-1 line
clock:
H801TOPA
(configured with
the H801CSSA
daughter board)
or H801TOPA
(configured with
the H801O2CE
daughter board).
l E1 line clock:
H801TOPA
(configured with
the H801NH1A
daughter board),
H801TOPA
(configured with
the H801EH1A
daughter board)
or H802EDTB.
l T1 line clock:
H802EDTB
SmartAX MA5600T/MA5603T/MA5608T Multi-service
Access Module
Commissioning and Configuration Guide 14 FTTM Configuration (Base Station Access)
Issue 01 (2014-04-30) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
1379

Table of Contents

Other manuals for Huawei SmartAX MA5608T

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Huawei SmartAX MA5608T and is the answer not in the manual?

Huawei SmartAX MA5608T Specifications

General IconGeneral
Dual Power SupplyYes
Humidity5% to 95% (non-condensing)
Uplink Slots2
Maximum GPON Ports16
Input Voltage Range-38.4 V DC to -72 V DC
Device TypeOLT
Power Supply-48 V DC
Operating Temperature-25°C to +55°C
Storage Temperature-40°C to 70°C
Switching Capacity128 Gbps
PortsGPON, XG-PON, 10GE

Related product manuals