huawei(config)#display if-mgcp all
--------------------------------------------------------------------------
MGID State MGPort MGIP MGCPort MGCIP/DomainName
--------------------------------------------------------------------------
0 Normal 2727 10.10.10.10 2727 10.10.20.20
--------------------------------------------------------------------------
Step 8 Configure the PSTN user data.
Add POTS users (phones 0-31) to ensure that users can go online.
huawei(config)#esl user
huawei(config-esl-user)#mgpstnuser batadd 0/3/0 0/3/31 0
huawei(config-esl-user)#quit
Step 9 Configure the polarity reversal accounting function.
Configure the physical attributes of the PSTN port to which the users belong to support the
polarity reversal pulse, so that the users can support the polarity reversal accounting.
huawei(config)#pstnport
huawei(config-pstnport)#pstnport attribute batset 0/3/0 0/3/31 reverse-pole-pulse
enable
huawei(config-pstnport)#quit
Step 10 Save the data.
huawei(config)#save
----End
Result
After the interface data and the PSTN user data corresponding to the MG interface are configured
on the MGC, check whether the VoIP services can be provisioned normally. In the normal state,
phones 0-31 can make phone calls to each other:
l The caller can hear the dial tone after picking up the phone.
l When the caller dials the phone number of the callee, the phone of the callee can ring
normally, and the caller can hear the ring back tone.
l The caller and the callee can communicate with each other successfully.
l After the callee hangs up the phone, the caller can hear the busy tone.
Configuration File
The following describes the configuration file of this configuration example. Note that certain
steps must be performed manually and the configuration file cannot be imported directly.
Configure the upstream VLAN interface.
vlan 20 standard
port vlan 20 0/19 0
interface vlanif 20
ip address 10.10.10.10 24
quit
Configure the media and signaling IP address pools.
voip
ip address media 10.10.10.10 10.10.10.1
ip address signaling 10.10.10.10
quit
SmartAX MA5600T/MA5603T/MA5608T Multi-service
Access Module
Commissioning and Configuration Guide
3 Configuring the DSLAM Services
Issue 01 (2014-04-30) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
315

Table of Contents

Other manuals for Huawei SmartAX MA5608T

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Huawei SmartAX MA5608T and is the answer not in the manual?

Huawei SmartAX MA5608T Specifications

General IconGeneral
Dual Power SupplyYes
Humidity5% to 95% (non-condensing)
Uplink Slots2
Maximum GPON Ports16
Input Voltage Range-38.4 V DC to -72 V DC
Device TypeOLT
Power Supply-48 V DC
Operating Temperature-25°C to +55°C
Storage Temperature-40°C to 70°C
Switching Capacity128 Gbps
PortsGPON, XG-PON, 10GE