Create a GPON ONT service profile, named ftth. Configure the capability set of the ETH
port and POTS port to adaptive. Then the system automatically adapts to the ONT
according to the actual capability of the online ONT.
huawei(config)#ont-srvprofile gpon profile-name ftth
huawei(config-gpon-srvprofile-1)#ont-port eth adaptive pots adaptive
After the configurations are complete, run the commit command to apply the parameters
setting.
huawei(config-gpon-srvprofile-1)#commit
huawei(config-gpon-srvprofile-1)#quit
4. (Optional) Add an alarm profile.
l The default GPON alarm profile 1 is used. The alarm thresholds of the default alarm
profile are 0, which indicates that no alarm is generated.
l In this example, the default alarm profile is used, and therefore the configuration of the
alarm profile is not required.
l Run the gpon alarm-profile add command to configure a GPON alarm profile, which
is used for monitoring the performance of an activated ONT line.
Step 2 Add an ONT.
Connect two ONTs to GPON port 0/1/0. Set the ONT IDs to 1 and 2, SNs to
32303131D659FD40 and 6877687714852901, passwords to 0100000001 and 0100000002,
discovery mode for password authentication to once-on, and management mode to OMCI. Bind
the two ONTs to ONT line profile ftth and ONT service profile ftth.
There are two methods of adding an ONT: add an ONT offline and confirm an automatically
discovered ONT.
l Add ONTs offline.
If the password of an ONT is known, run the ont add command to add an ONT offline.
huawei(config)#interface gpon 0/1
huawei(config-if-gpon-0/1)#ont add 0 1 password-auth 0100000001 once-on no-aging
omci ont-lineprofile-name
ftth ont-srvprofile-name ftth
huawei(config-if-gpon-0/1)#ont add 0 2 password-auth 0100000002 once-on no-aging
omci ont-lineprofile-name
ftth ont-srvprofile-name ftth
l Confirm automatically discovered ONTs.
If the password or SN of an ONT is unknown, run the port portid ont-auto-find command
in GPON mode to enable the ONT auto-discovery function of the GPON port. Then, run the
ont confirm command to confirm the ONT.
huawei(config)#interface gpon 0/1
huawei(config-if-gpon-0/1)#port 0 ont-auto-find enable
huawei(config-if-gpon-0/1)#display ont autofind 0
//After this command is executed, the information about all ONTs connected to
the GPON port through optical splitters is displayed.
huawei(config-if-gpon-0/1)#ont confirm 0 ontid 1 sn-auth 32303131D659FD40 omci
ont-lineprofile-name
ftth ont-srvprofile-name ftth
huawei(config-if-gpon-0/1)#ont confirm 0 ontid 2 sn-auth 6877687714852901 omci
ont-lineprofile-name
ftth ont-srvprofile-name ftth
SmartAX MA5600T/MA5603T/MA5608T Multi-service
Access Module
Commissioning and Configuration Guide
9 FTTH Configuration
Issue 01 (2014-04-30) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
584

Table of Contents

Other manuals for Huawei SmartAX MA5608T

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Huawei SmartAX MA5608T and is the answer not in the manual?

Huawei SmartAX MA5608T Specifications

General IconGeneral
Dual Power SupplyYes
Humidity5% to 95% (non-condensing)
Uplink Slots2
Maximum GPON Ports16
Input Voltage Range-38.4 V DC to -72 V DC
Device TypeOLT
Power Supply-48 V DC
Operating Temperature-25°C to +55°C
Storage Temperature-40°C to 70°C
Switching Capacity128 Gbps
PortsGPON, XG-PON, 10GE