l Run the gpon alarm-profile add command to configure a GPON alarm profile, which
is used for monitoring the performance of an activated ONT line.
Step 2 Add an ONT.
Connect two ONTs to GPON port 0/1/0. Set the ONT IDs to 1 and 2, SNs to
32303131D659FD40 and 6877687714852901, passwords to 0100000001 and 0100000002,
discovery mode for password authentication to once-on, and management mode to OMCI. Bind
the two ONTs to ONT line profile ftth and ONT service profile ftth.
There are two methods of adding an ONT: add an ONT offline and confirm an automatically
discovered ONT.
l Add ONTs offline.
If the password of an ONT is known, run the ont add command to add an ONT offline.
huawei(config)#interface gpon 0/1
huawei(config-if-gpon-0/1)#ont add 0 1 password-auth 0100000001 once-on no-aging
omci ont-lineprofile-name
ftth ont-srvprofile-name ftth
huawei(config-if-gpon-0/1)#ont add 0 2 password-auth 0100000002 once-on no-aging
omci ont-lineprofile-name
ftth ont-srvprofile-name ftth
l Confirm automatically discovered ONTs.
If the password or SN of an ONT is unknown, run the port portid ont-auto-find command
in GPON mode to enable the ONT auto-discovery function of the GPON port. Then, run the
ont confirm command to confirm the ONT.
huawei(config)#interface gpon 0/1
huawei(config-if-gpon-0/1)#port 0 ont-auto-find enable
huawei(config-if-gpon-0/1)#display ont autofind 0
//After this command is executed, the information about all ONTs connected to
the GPON port through optical splitters is displayed.
huawei(config-if-gpon-0/1)#ont confirm 0 ontid 1 sn-auth 32303131D659FD40 omci
ont-lineprofile-name
ftth ont-srvprofile-name ftth
huawei(config-if-gpon-0/1)#ont confirm 0 ontid 2 sn-auth 6877687714852901 omci
ont-lineprofile-name
ftth ont-srvprofile-name ftth
NOTE
If multiple ONTs of the same type bound to the same line profile or service profile are connected to the same
port, you can bulk add ONTs by bulk confirming automatically discovered ONTs to make configuration
easier and more efficient. To do so, the preceding command can be modified as follows:
huawei(config-if-gpon-0/1)#ont confirm 0 all sn-auth omci ont-lineprofile-name
ftth
ont-srvprofile-name ftth
l (Optional) Bind the alarm profile to the ONT.
The default profile 1 is used in this example.
huawei(config-if-gpon-0/1)#ont alarm-profile 0 1 profile-id 1
huawei(config-if-gpon-0/1)#ont alarm-profile 0 2 profile-id 1
Step 3 Check ONT status.
After an ONT is added, run the display ont info command to query the current status of the
ONT. Ensure that Config flag of the ONT is active, Run State is online, Config state is
normal, and Match state is match.
huawei(config-if-gpon-0/1)#display ont info 0 1
---------------------------------------------------------------------
SmartAX MA5600T/MA5603T/MA5608T Multi-service
Access Module
Commissioning and Configuration Guide
9 FTTH Configuration
Issue 01 (2014-04-30) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
634

Table of Contents

Other manuals for Huawei SmartAX MA5608T

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Huawei SmartAX MA5608T and is the answer not in the manual?

Huawei SmartAX MA5608T Specifications

General IconGeneral
Dual Power SupplyYes
Humidity5% to 95% (non-condensing)
Uplink Slots2
Maximum GPON Ports16
Input Voltage Range-38.4 V DC to -72 V DC
Device TypeOLT
Power Supply-48 V DC
Operating Temperature-25°C to +55°C
Storage Temperature-40°C to 70°C
Switching Capacity128 Gbps
PortsGPON, XG-PON, 10GE