EasyManuals Logo

Huawei SmartAX MA5608T User Manual

Huawei SmartAX MA5608T
1979 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #876 background imageLoading...
Page #876 background image
Applicatio
n Scenario
Servic
e Type
VLA
N
Plan
VLAN Translation Remarks
ONU OLT
FTTB or
FTTC
Ethernet
cascading
(centralized
management
for GE
remote
extended
subracks)
Multic
ast
service
One-
tag
VLA
N
soluti
on
HGWs (xDSL
upstream
transmission)
when MVLANs
on HGW side and
network side are
different:
l Upstream
IGMP
packets: The
extended
subrack
performs
IGMP proxy
to terminate
IGMP
packets
transmitted
from the user
side,
encapsulate
the packets
with an
MVLAN tag
on the
network side,
and send the
packets to the
extending
board.
l Downstream
multicast
service flows:
The extended
subrack
replicates
multicast
packets based
on user ports,
and
multicasts the
packets
among
MVLANs
(user VLAN
<- MVLAN).
l Upstream
IGMP
packets: The
master
subrack
performs
IGMP proxy
to terminate
IGMP
packets
transparently
transmitted
from the
extending
board and
reported by
the extended
subrack,
encapsulate
the packets
with an
MVLAN tag
on the
network side,
and send the
packets to the
upper-layer
network.
l Downstream
multicast
service flows:
The control
board in the
master
subrack
replicates
multicast
packets based
on Ethernet
extending
boards, and
the Ethernet
extending
boards
replicate
multicast
This solution is
recommended.
SmartAX MA5600T/MA5603T/MA5608T Multi-service
Access Module
Commissioning and Configuration Guide 11 FTTB and FTTC Solution Configuration
Issue 01 (2014-04-30) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
851

Table of Contents

Other manuals for Huawei SmartAX MA5608T

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Huawei SmartAX MA5608T and is the answer not in the manual?

Huawei SmartAX MA5608T Specifications

General IconGeneral
Dual Power SupplyYes
Humidity5% to 95% (non-condensing)
Uplink Slots2
Maximum GPON Ports16
Input Voltage Range-38.4 V DC to -72 V DC
Device TypeOLT
Power Supply-48 V DC
Operating Temperature-25°C to +55°C
Storage Temperature-40°C to 70°C
Switching Capacity128 Gbps
PortsGPON, XG-PON, 10GE

Related product manuals