Hardware Installations and Upgrades 
 
106          Intel
®
 Server Board S2600CP Intel
®
 Server System P4000CP Family Service Guide 
 
The number of SATA ports available from the integrated AHCI-capable SATA Controller is 
dependent on the specific server board installed in the system. Different server board designs 
expose different SATA port configurations.  
Back to [Mass Storage Controller Configuration Screen]  
2.  SATA/SAS Controller Configuration 
Option Values:    <SCU SAS/SATA Port Configuration> 
One of these strings
: 
Controller is disabled 
4 ports in SATA mode 
4 ports in SAS mode 
8 ports in SATA mode 
8 ports in SAS mode 
Help Text:    <None> 
Comments:   Information only
. This is a display showing the number of ports which 
are available through the SCU controller, and whether they are configured for SATA or SAS. 
This information is also displayed during POST in the POST Diagnostic Screen. 
Various SATA/SAS Capable Controller configurations require the installation of Intel
®
 RAID 
C600 Upgrade Keys: 
4 port SATA requires no key
 or AXXRKSATA4R5 key 
4 port SAS requires AXXRKSAS4 or AXXRKSAS4R5 key 
8 port SATA requires AXXRKSATA8 or AXXRKSATA8R5 key 
8 port SAS requires AXXRKSAS8 or AXXRKSAS8R5 key 
Back to [Mass Storage Controller Configuration Screen]  
3.  AHCI Capable SATA Controller 
Option Values:    Disabled 
   Compatibility 
   Enhanced 
 AHCI 
   RAID Mode 
Help Text: 
- Compatibility provides PATA emulation on the SATA device 
- Enhanced provides Native SATA support 
- AHCI enables the Advanced Host Controller Interface, which provides Enhanced SATA 
functionality 
- RAID Mode  provides host based RAID support on the onboard SATA ports 
Comments:    This option configures the onboard AHCI-capable SATA controller 
which is distinct from the SCU.  
If the SATA Controller is Disabled, the SATA Ports will not operate. and any installed SATA 
devices will be unavailable.