Hardware Installations and Upgrades
122 Intel
®
Server Board S2600CP Intel
®
Server System P4000CP Family Service Guide
Comments: This is a security option. When Disabled, the system cannot be booted
directly to a USB device of any kind. USB Mass Storage devices may still be used for data
storage.
If the USB controller
setting is Disabled, this field is grayed out and inactive.
Back to [USB Configuration]
6. Device Reset Timeout
Option Values: 10 seconds
20 seconds
30 seconds
40 seconds
Help Text:
USB Mass Storage device Start Unit command timeout.
Setting to a larger value provides more time for a mass storage device to be ready, if
needed.
Comments: If the USB controller
setting is Disabled, this field is grayed out and
inactive.
Back to [USB Configuration]
System Acoustic and Performance Configuration
The System Acoustic and Performance Configuration screen allows the user to configure the thermal
control behavior of the system with respect to what parameters are used in the system’s Fan Speed
Control algorithms.
This screen is only available for platforms which have a BMC. Non-BMC platforms use a different Fan
Speed Control mechanism configured from the Hardware Monitor screen.
To access this screen from the Main screen, select Advanced > System Acoustic and Performance
Configuration. To move to another screen, press the <Esc> key to return to the Advanced screen, then
select the desired screen.