SV-DA200 series AC servo drive Function codes
-164-
P4.92*
Restore to factory value
Setting range
Default
Unit
Available mode
01
0
-
P
S
T
After this operation, all parameters (P0P6 group) can be restored to the default value.
Setting value
Function
[0]
Disabled
1
Enabled
P4.92*
Data size
16bit
Data format
DEC
Modbus address
1984, 1985
CANopen address
0x245C, 0x00
P4.93*
Reading enable of fault
record
Setting range
Default
Unit
Available mode
01
0
-
P
S
T
This parameter can set the enabling of reading the fault record.
Setting value
Function
[0]
Disabled
1
Enabled
P4.93*
Data size
16bit
Data format
DEC
Modbus address
1986, 1987
CANopen address
0x245D, 0x00
P4.94*
Clearing enable of fault
record
Setting range
Default
Unit
Available mode
01
0
-
P
S
T
This parameter can set the enabling of clearing the fault record.
Setting value
Function
[0]
Disabled
1
Enabled
P4.94*
Data size
16bit
Data format
DEC
Modbus address
1988, 1989
CANopen address
0x245E, 0x00
P4.95*
Group number of fault
record
Setting range
Default
Unit
Available mode
09
0
-
P
S
T
This parameter can set the group number of fault record.
0 corresponds to the group 1 fault recorded which is also the latest one, 9 corresponds to group
10 fault recorded which is also the earliest one.
P4.95*
Data size
16bit
Data format
DEC
Modbus address
1990, 1991
CANopen address
0x245F, 0x00
P4.96*
Reserved
Setting range
Default
Unit
Available mode
-
-
-
P
S
T
It is forbidden to modify this parameter
P4.96*
Data size
16bit
Data format
DEC
Modbus address
1992, 1993
CANopen address
0x2460, 0x00