SV-DA200 series AC servo drive Control mode applications
-50-
4.3 Standard wiring of the torque mode
Torque control mode
Speed limit input
(-10V~+10V)
Torque command input
(-10V~+10V)
EMG 39
SON 16
ZRS 37
POT 3
NOT 4
CLA 10
SPD1 34
SPD2 17
T/SIGN 18
PLC 22
Gain switching
Torque command
sign
Internal speed
command 2
Internal speed
command 1
Alarm clearing
Negative direction
drive disabled
Emergency stop
Servo enabling
Zero speed clamp
Positive direction
drive disabled
COM- 12
COM+ 2
24V 40
Internal DC24V power
Note: Capacity 100mA
12 COM-
15 ALM
14 RDY
29 ZSO
11 TRCH
13 LM
9 BRK
AD2 20
GND 19
AD3 7
GND 8
FG
21 AO1
5 GND
25 AO2
6 GND
FG
Torque monitoring output
Speed monitoring output
Fault
Servo ready
Speed zero
Torque reaching
Torque limiting
Brake release
Ref
Max load capacity
of output terminal
is DC30V, 50mA
Note: User-supplied power
DC12~24V
- +
Note: User-supplied power
VccDC30V
- +
󴘐
󴘐
Frequency
divider
36 OCA
External
controller
44 OA+
43 OA-
41 OB+
42 OB-
FG
26 OCZ
30 OCB
AM26LS32
or equivalent chip
V
cc
DC30V;
OCA/B/Z
output current
50mA
28 OZ+
27 OZ-
High speed optical
coupler
35 GND
GND
- +
Vcc
5 GND
CN1
Output voltage range:
DC -10V~+10V;
Max output
current:3mA
DI input
common port
DO output common
ground
Note: 1. ( ) is shielded twisted pair;
2. ( ) is power which is provided by the user;
3. ( ) is GND, pin numbers are 5/6/8/19/35.
DO output
common ground