SV-DA200 series AC servo drive Appendix
-292-
10.4 Fault code
The format of fault code is ErXX-X, of which, XX is the master code and X is the sub code.
Example: , the master code is 01, the sub code is 0. Other codes are displayed in
the similar way.
Fault
code
Name
Feature
History record
Can be cleared
Disable
Er01-0
IGBT fault
Er01-1
Brake tube fault (7.5kW and above model)
Er02-0
Encoder faultThe encoder wire break
Er02-1
Encoder faultEncoder feedback error is too large
Er02-2
Encoder faultParity error
Er02-3
Encoder faultCRC error
Er02-4
Encoder faultFrame error
Er02-5
Encoder faultA short frame error
Er02-6
Encoder faultEncoder overtime
Er02-7
Encoder faultFPGA overtime
Er02-8
Encoder faultLow voltage alarm of the encoder
Er02-9
Encoder faultUndervoltage alarm of the encoder
Er02-a
Encoder faultEncoder over-temperature
Er02-b
Encoder faultEEPROM write error
Er02-c
Encoder faultEEPROM no data
Er02-d
Encoder faultEEPROM data check error
Er03-0
Current sensor faultU phase current sensor fault
Er03-1
Current sensor faultV phase current sensor fault
Er03-2
Current sensor faultW phase current sensor fault
Er04-0
System initialization fault
Er05-1
Setting faultMotor model does not exist
Er05-2
Setting faultMotor and drive model does not match
Er05-3
Setting faultSoftware limit setting error
Er05-4
Setting faultHoming mode setting fault
Er05-5
Setting faultBit control travel overflow fault
Er07-0
Regeneration discharge overload fault
Er08-0
Analog input overvoltage faultAnalog input 1
Er08-1
Analog input overvoltage faultAnalog input 2
Er08-2
Analog input overvoltage faultAnalog input 3

Table of Contents