SV-DA200 series AC servo drive Wiring instruction
-34-
3.1.3 Cable diameter of main circuit
Small power range (100W5.5kW) main circuit cable diameter table
Drive model
Recommended cable
diameter (mm
2
)
Connectable cable
diameter (mm
2
)
Terminal
screw
specification
Tightening
torque
(Nm)
L1\L2\L3
UVW
PE
L1C\L2C
L1\L2\L3
UVW
(+), B2,
B3, (-)
PE
SV-DA200-0R1-2
0.75
0.75
0.75
0.754
0.754
0.754
M2.5
0.30.6
SV-DA200-0R2-2
SV-DA200-0R4-2
SV-DA200-0R7-2
SV-DA200-1R0-2
1.5
1.5
0.75
1.54
1.54
1.54
M2.5
0.30.6
SV-DA200-1R5-2
SV-DA200-2R0-2
2.5
2.5
0.75
2.54
2.54
2.54
M4
1.21.5
SV-DA200-3R0-2
SV-DA200-4R4-2
SV-DA200-1R0-4
1.5
1.5
0.75
1.54
1.54
1.54
M2.5
0.30.6
SV-DA200-1R5-4
SV-DA200-2R0-4
SV-DA200-3R0-4
SV-DA200-4R4-4
2.5
2.5
0.75
2.56
2.56
2.56
M4
1.21.5
SV-DA200-5R5-4
Medium power range (7.5kW55kW) main circuit cable diameter table
Drive model
Recommended
cable diameter
(mm
2
)
Connectable cable diameter
(mm
2
)
Terminal
screw
specification
Tightening
torque
(Nm)
RST
UVW
PE
RST
UVW
(+), PB, (-)
PE
SV-DA200-7R5-4
6
6
616
610
610
M5
22.5
SV-DA200-011-4
10
10
1016
1016
616
M5
22.5
SV-DA200-015-4
16
16
1625
1625
1016
M6
46
SV-DA200-022-4
25
16
2550
2550
1625
M8
911
SV-DA200-037-4
35
16
2550
2550
1625
M8
911
SV-DA200-045-4
50
25
3595
2595
2535
The terminal adopts nuts,
users are suggested to use
spanners or sleeves
SV-DA200-055-4
70
35
5095
5095
2535