SCPI Conformance Information
J-10
[:SENse[1]]
:CURRent:AC
:DIGits <n>
:AUTO <b>
:AUTO ONCE
:AUTO?
:DIGits?
:AVERage
:TCONtrol <name>
:TCONtrol?
:COUNt <n>
:COUNt?
:ADVanced
:NTOLerance <n>
:NTOLerance?
[:STATe] <b>
[:STATe]?
[:STATe] <b>
[:STATe]?
:AUTO <b>
:AUTO ONCE
:AUTO?
:DETector
[:FUNCtion] <name>
[:FUNCtion]?
:CURRent:DC
:APERture
:AUTO <b>
:AUTO ONCE
:AUTO?
:NPLCycles
:AUTO <b>
:AUTO ONCE
:AUTO?
:RANGe
:AUTO
:ULIMit <n>
:ULIMit?
:LLIMit <n>
:LLIMit?
:REFerence
:ACQuire
:DIGits <n>
:AUTO <b>
:AUTO ONCE
:AUTO?
:DIGits?
:AVErage
:TCONtrol <name>
:TCONtrol?
:COUNt <n>
:COUNt?
Specify measurement resolution (4 to 8).
Enable (1 or ON) or disable (0 or OFF) auto resolution.
Enable and then disable auto resolution.
Query auto resolution (0 or 1).
Query resolution.
Path to configure and control the filter.
Select filter type: MOVing, REPeat.
Query filter type.
Specify filter count (1 to 100).
Query filter count.
Path to configure and control advanced filter.
Specify noise tolerance level (0 to 100 percent).
Query noise tolerance level.
Enable (1 or ON) or disable (0 or OFF) advanced filter.
Query state of advanced filter.
Enable (1 or ON) or disable (0 or OFF) filter.
Query state of digital filter.
Enable (1 or ON) or disable (0 or OFF) auto filter.
Enable and then disable auto filter.
Query auto filter.
Path to select function:
Select type of AC measurement: RMS, AVERage.
Query detector function.
Path to configure DC current.
Specify integration rate in seconds (166.67e-6 to 200e-3).
Enable (1 or ON) or disable (0 or OFF) auto resolution.
Enable and then disable auto resolution.
Query auto resolution (0 or 1).
Specify integration rate (number of line cycles; 0.01 to 10).
Enable (1 or ON) or disable (0 or OFF) auto NPLC.
Enable and then disable auto NPLC.
Query auto line cycle integration (0 or 1).
Path to configure measurement range:
Set range based on present input signal.
Specify upper limit for auto range (0 to 2.1).
Query upper limit.
Specify lower limit for auto range (0 to 2.1).
Query lower limit.
Specify reference (REL) value (-2.1 to +2.1).
Use input signal as reference.
Specify measurement resolution (4 to 8).
Enable (1 or ON) or disable (0 or OFF) auto resolution.
Enable and then disable auto resolution.
Query auto resolution (0 or 1).
Query resolution.
Path to configure and control the filter.
Select filter type: MOVing, REPeat.
Query filter type.
Specify filter count (1 to 100).
Query filter count.
Table J-2 (cont.)
Syntax of non-SCPI commands implemented by Model 2001
Command Description

Table of Contents

Other manuals for Keithley 2001

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Keithley 2001 and is the answer not in the manual?

Keithley 2001 Specifications

General IconGeneral
BrandKeithley
Model2001
CategoryMultimeter
LanguageEnglish

Related product manuals