OPERATION MACHINE OPERATIONS AND CONTROLS
3-209
q When starting the engine again after it has stopped, move
fuel shut-off lever (1) up again and check that fuel shut-off
lever (1) does not move.
Fuel shut-off valve (3) is installed to the bottom of the fuel tank
to reduce the spread of fire if any fire should occur. This makes
it possible to prevent the fuel inside the fuel tank from flowing
out even if the fuel piping hoses are burned.
Fuel shut-off valve (3) is connected to fuel shut-off lever (1) and
fuel shut-off cable (2) and interlocks with them.
When having stopped the engine, operating the fuel shut-off
valve, bleed air from the fuel circuit before starting the engine
again.
Even if fuel shut-off lever (1) or the fuel shut-off cable are oper-
ated, the engine will stop, but engine emergency stop lamp (4)
does not light up.