LONG TERM STORAGE OPERATION
3-238
LONG TERM STORAGE 3
BEFORE STORAGE 3
To protect the hydraulic cylinder piston rod while in stor-
age, keep the work equipment in the posture shown at
right.
(This prevents rust from developing on the piston rod)
When putting the machine in storage for a long time (more than one month), do as follows.
q Clean and wash all parts, then store the machine indoors. If the machine has to be stored outdoors, select
level ground and cover the machine with canvas.
q Completely fill the fuel tank. This prevents moisture from collecting.
q Lubricate and change the oil before storage.
q Coat the exposed portion of the hydraulic cylinder piston rod with grease.
q After shutting off the engine, wait over one minute, then turn the battery isolator switch to the OFF position.
Put a cover on the battery during storage.
q Lock each control lever and pedal with the lock lever and pedal lock.
q To prevent rust, fill with coolant to give a density of at least 30% for the engine coolant.
DURING STORAGE 3
If it is necessary to perform the rust-prevention operation while the machine is indoors, open the doors
and windows to improve ventilation and prevent gas poisoning.
q During storage, operate and move the machine for a short distance once a month so that a new film of oil will
coat moving parts. At the same time, also charge the battery.
q When operating the work equipment, wipe off all the grease from the hydraulic cylinder rods.
q If the machine is equipped with an air conditioner, operate the air conditioner for 3 to 5 minutes once a month
to lubricate all parts of the air conditioner compressor. Always run the engine at low idle when doing this. In
addition, check the refrigerant level twice a year.