5-10 BA 35101/02/03 EN – Edition 1.0 * 35101_02_03b510.fm
Maintenance
Filling up coolant
Danger!
Danger of burns! Never open the coolant tank and never drain coolant if the
warm engine is running since the cooling system is under high pressure!
☞ Wait at least 10 minutes after stopping the engine!
☞ Wear protective gloves and clothing
☞ Always actuate the safety valve first on the filler cap of the expansion tank.
To do this:
☞ Open the cap to the first notch and release the pressure
☞ Fill up coolant as follows
• Park the machine on level ground
• Lower the loader unit
• Apply the parking brake
• Switch off ignition and remove the ignition key
• Allow the engine/cooling system to cool down
• Release the overpressure in the coolant expansion tank. To do this: open cap A to
the first notch and release the pressure
• Open filler cap A fully
• Fill up coolant to the MAX mark B
➥Use brand-name antifreeze compounds with anticorrosion additives –seeFluids
and lubricants on page 5-43
• Close filler cap A
☞ Check the coolant level
• Open the heating circuit fully
• Start and warm up the engine
• Stop the engine
• Check the coolant level again
➥If necessary, fill in coolant and repeat the procedure until reaching the correct
coolant level
• Check the cooling system and the heating water circuit for leaks
• Have leaks immediately repaired by an authorised workshop
Fig. 164: Filling up coolant in the expansion tank
MIN
B
A
MAX

Table of Contents