5-10 BA 35101/02/03 EN – Edition 1.0 * 35101_02_03b510.fm
Maintenance
Filling up coolant
Danger!
Danger of burns! Never open the coolant tank and never drain coolant if the
warm engine is running since the cooling system is under high pressure!
Wait at least 10 minutes after stopping the engine!
Wear protective gloves and clothing
Always actuate the safety valve first on the filler cap of the expansion tank.
To do this:
Open the cap to the first notch and release the pressure
Fill up coolant as follows
Park the machine on level ground
Lower the loader unit
Apply the parking brake
Switch off ignition and remove the ignition key
Allow the engine/cooling system to cool down
Release the overpressure in the coolant expansion tank. To do this: open cap A to
the first notch and release the pressure
Open filler cap A fully
Fill up coolant to the MAX mark B
Use brand-name antifreeze compounds with anticorrosion additives –seeFluids
and lubricants on page 5-43
Close filler cap A
Check the coolant level
Open the heating circuit fully
Start and warm up the engine
Stop the engine
Check the coolant level again
If necessary, fill in coolant and repeat the procedure until reaching the correct
coolant level
Check the cooling system and the heating water circuit for leaks
Have leaks immediately repaired by an authorised workshop
Fig. 164: Filling up coolant in the expansion tank
MIN
B
A
MAX