3-16 BA 35101/02/03 EN – Edition 1.0 * 35101_02_03b330.fm
Operation
Starting the engine
The ignition lock is located on the right-hand side control lever console.
Apply the parking brake to the last notch
Turn the ignition key (preheating start switch 19) to position “1
The following telltales must come on
Engine oil pressure telltale 82
Telltale 81 if the parking brake is applied
Alternator charge function telltale 80
Automatic preheating telltale 85, comes on for about 30 – 60 seconds at normal
temperatures (up to 0°), and for about 60 90 seconds at low temperatures
(below 0°)
The intake air is preheated via a temperature-dependent time lag relay, and telltale
85 goes out once the temperature is reached
After telltale 85 (automatic preheating) has gone out:
Start the engine as follows:
Press the accelerator pedal through about 1/4 of its travel
Turn the ignition key to position 3 and hold it in this position until the engine starts
Release the ignition key
Check that the following telltales have gone out:
Engine oil pressure telltale 82
Alternator charge function telltale 80
Cold starter telltale 85
Caution!
In order to avoid damage to the engine and the exhaust turbocharger due to
insufficient lube oil supply:
Do not run the cold engine at full throttle when starting
Let the engine warm up at low idling speed (for about 30 seconds)
Replace defective telltales immediately
Fig. 44: Preheating start switch
Fig. 45: Indicating instrument telltales
81 8280
19
1
0
2
3
85