5-22 BA 35101/02/03 EN – Edition 1.0 * 35101_02_03b510.fm
Maintenance
Setting the lubrication and break times
Break times and lubrication times are set with the notched switches S and P in the window
of the controls.
☞ Remove the red frame on the protective motor housing of the pump with a flat screw-
driver to set the time
☞ Slacken the four cross-slotted screws and remove the transparent cover
☞ Set the break time P and the lubrication time S with a flat screwdriver
Lubrication times (S):
➥1 to 16 minutes (16 notches, 1 minute each)
➥2 to 32 minutes (16 notches, 2 minutes each)
Break time (P):
➥0.5 to 8 h (16 notches, 0.5 h each)
Yellow LED (L)
➥(B) lubrication system in operation
➥(A) lubrication under progress: 0.5 seconds LED ON/0.5 seconds LED OFF
☞ Install the transparent cover (window) once the settings are carried out
Water can penetrate into the controls and damage them if the cover is not
fitted and closed correctly!
Filling the central lubrication system
The lubrication system is filled via conical grease nipple 1 or a fill coupling with a manual or
pneumatic grease gun.
Use only commercially available greases up to NLGI-Kl. 2 to avoid damage to
the lubrication system and the lubrication points!
☞ –seeFluids and lubricants on page 5-43
Break time
Fig. 178: Setting the lubrication times
S P L
B
A
Lubrication time
Fig. 179: Filling the central lubrication system
1