7 REFERENCE CONFIG MENU
66
7.5 Setting the Recovery Operation
Under RECOVERY/TRACKING on the REFERENCE CONFIG menu, you can set the recovery
operation that takes place when the reference signal is lost during genlock operation.
This menu appears when REFERENCE SOURCE is set to an option other than INTERNAL.
7.5.1 Selecting the Recovery Mode
To select the operation to perform when the reference signal recovers after it is lost during
genlock operation, follow the procedure below.
Procedure
REFERENCE CONFIG > RECOVERY/TRACKING > MODE
Parameters
AUTO: Relocks onto the reference signal.
MANUAL: Stay-in-sync operation is held. Use REFERENCE READJUST to
relock.
Initial value
AUTO
7.5.2 Selecting the Relock Speed (Auto)
When RECOVERY MODE is set to AUTO, to select the relock speed, follow the procedure below.
From the time this instrument is started until the time set with IMMEDIATE MODE TIME elapses,
the instrument operates with IMMEDIATE regardless of the selection made here. (This does not
apply when REFERENCE SOURCE is set to GNSS.)
Procedure
REFERENCE CONFIG > RECOVERY/TRACKING > AUTO SETTING
Parameters
IMMEDIATE: Immediately relocks onto the reference signal. This cannot be
selected when REFERENCE SOURCE is set to GNSS.
FAST: Quickly relocks onto the reference signal.
SLOW: Slowly relocks onto the reference signal.
Initial value
FAST