3 SPECIFICATIONS
11
3.3 Standards
3.3.1 LT4670
General Specifications
Environmental Conditions
Operating Temperature 0 – 40°C
Operating Humidity Range 85% RH or less (no condensation)
Optimal Temperature 10 – 35°C
Operating Environment Indoors
Operating Altitude Up to 2,000 m
Overvoltage Category II
Pollution Degree 2
Power Supply
Voltage 100 – 240 VAC
Voltage Variation ±10%
Power Consumption 150 W max. (when all options are used)
Dimensions 482 (W) × 44 (H) × 400 (D) mm (excluding
protrusions)
Weight 4.15 kg (excluding options)
5.37 kg (including options)
Accessories Power cord
AC cord clamp
General safety summary
Sold Separately SFP transceiver (LC2141 / LC2142 / LC2148 / LC2149)
GNSS antenna
Fan unit (LP2184)
LTC cable (for connecting LC2185 and LT4448)
L-SYNC cable (LC2186)
Power Supply Unit
Number of Units in Main Unit
Standard 1
Maximum 2 (when LT4670-SER11 is installed)
Power Supply Redundancy When LT4670-SER11 is installed
Replacement Method The installed LT4670-SER11 can be replaced without
turning off the power of the main unit.
Alarm A power supply alarm is indicated on the LED and LCD
and notified by an SNMP (future support) trap.
Fan Unit
Number of Fans 2 (one on front, one on rear)
Replacement Method The fan can be stopped using the panel and replaced
without turning off the power of the main unit.
Alarm A fan alarm is indicated on the LED and LCD and
notified by an SNMP (future support) trap.