136
Open the suction valve so that no liquid
can escape from the chemical inductor
tank.
After rinsing the chemical inductor,
switch the following rocker arms down-
wards to OFF to close the valves:
Cleaning nozzle or canister rinsing nozz-
le
Close the suction valve.
Switch the selection valve to main tank.
Switch the diverting valve to spraying.
Due to the limited content of the clean water tank, we recommend
for
cleaning empty spray agent canisters
and for rinsing the chemical inductor with clean water:
Suck in clean water with a filling hose via the selection valve,
see «Filling the main tank, page 117».