Operation
155
Equipment-specific differences when folding in:
Comfort FS 1:
Spray boom is completely folded in.
From Comfort FS 2 unit:
Spray booms can be folded in part width
sections.
The outer outriggers can be folded in
symmetrically or left in a reduced positi-
on. Booms 1 and 2 are folded in at once.
7.18 System cleaning with partially filled main container
ATTENTION
If distribution is interrupted, deposits from the spray solution can
contaminate the piping system and the nozzles.
Unless the spraying fluid is stirred, separation is possible. If the
spraying fluid is not stirred after interruption, the decomposed
spray solution may block up the piping system and the nozzles.
Rinse the piping system and nozzles before interruption.
After interruption, stir the spraying fluid in accordance with the
instructions in the spray solution's package leaflet.
Application: Distribution is interrupted,
e.g. work break or if the weather conditions
change.In this case, the main tank may still
contain spraying fluid.
General procedure:
Rinse the piping system prior to interrup-
tion.
Stir spraying fluid before resuming distri-
bution.

Table of Contents