Technical data
235
Maximum permissible angle (°):
Without wide angle joint
With wide angle joint
Working angle
25
25
For short period operation
with reduced power
45
80
Stationary
90
80
11.11 Pumps
Implement
Working pump
Agitator pump
2500
P260
3500
P260
4500
P200
P200
Data per pump
Type
P 260
P 200/P200
PTO shaft
DIN 9611 / ISO 500
Design
Piston diaphragm pump
Number of pistons
4
2 x 4
Connection
Hose
Internal Ø suction side, minimum
[mm]
50
50
Internal Ø pressure side, minimum
[mm]
31.00
31.50
Operating pressure [bar]
15
Nominal pressure [bar]
20
Permissible negative pressure [bar]
0.3
Maximum suction depth [m]
3