Technical data
238
11.13.1 Device system
Pressure
[bar]
Required pressure in the tractor hydraulics for the hydraulic
ram on the device side [bar]:
160
Maximum permissible:
200
The hydraulic system is filled with hydraulic oil HLP 46 in accordance with ISO VG
46; DIN 51 524 T.2.
11.13.2 Volumetric flow and pressure
Function
[l/min]
Folding the boom (P2/T2)
10
Height adjustment of the boom up to B30 (P1)
18
Electro-hydraulic operation up to B30 (P6T6) without steering
24
The information for electro-hydraulic operation also applies to devices equipped
with load sensing.
11.13.3 Pressure limit valves
The pressure limit valves are factory set to 150 bar and may not be adjusted.
11.14 Electronic pressure display
Type:
Liquid crystal display
Pressure detection:
electronic pressure sensor in the pipe cross-section of the
boom
Accuracy class:
1.6% of displayed value
Resolution [bar]:
0.1
Display range [bar]
0 16
Display area [cm]
4 x 1.5
Damping:
electronic

Table of Contents