257
Nozzle
(Colour)
Pressure
[bar]
l/min
UAN l/ha
H2O
UAN
km/h
6
8
10
14
18
20
(Black)
1.5
5.66
4.98
996
747
598
427
332
2.0
6.53
5.75
1149
862
690
493
383
3.0
8.00
7.04
1408
1056
845
604
469
4.0
9.24
8.13
1626
1220
976
697
542
Notes:
The table relates to a nozzle spacing of 50 cm and l/ha values based on a UAN
solution (28/1.28 kg/l).
A conversion factor must be applied to liquid fertilisers with a different density.
Jet direction against the direction of travel.
Spray pressure measured at the nozzle.
Lateral nozzle spacing 50 cm.
Spray height above the crop approx. 50 to 70 cm.
Spray pressure range 1.5 to 4.0 bar
The data and applications listed in the nozzle tables must always be taken into
account.
For accurate dosing, volumetric metering is recommended on first
use and annually thereafter .