Address Name Default seng Category Data type Factor A M
0x291F:002
(P317.02)
Skip frequencies: Skip bandwidth 1 0.0 Hz general U8 10 P -
0x291F:003
(P317.03)
Skip frequencies: Skip frequency 2 0.0 Hz general U16 10 P -
0x291F:004
(P317.04)
Skip frequencies: Skip bandwidth 2 0.0 Hz general U8 10 P -
0x291F:005
(P317.05)
Skip frequencies: Skip frequency 3 0.0 Hz general U16 10 P -
0x291F:006
(P317.06)
Skip frequencies: Skip bandwidth 3 0.0 Hz general U8 10 P -
0x291F:016 Skip frequencies: Status - (Read only) general U16 1 - -
0x291F:032 Skip frequencies: Input frequency x.xx Hz (Read only) general I32 100 - -
0x291F:033 Skip frequencies: Output frequency x.xx Hz (Read only) general I32 100 - -
0x2939
(P305.00)
Switching frequency 0 * general U8 1 P -
0x293A
(P116.00)
Actual switching frequency - (Read only) general U8 1 O t
0x2942:001
(P334.01)
Current controller parameters: Gain 42.55 V/A * MCTRL U32 100 P -
0x2942:002
(P334.02)
Current controller parameters: Reset me 4.50 ms * MCTRL U32 100 P -
0x2946:001
(P340.01)
Speed
limitaon: Upper speed limit 0 vel. unit general I32 480000
/2
31
OP r
0x2946:002
(P340.02)
Speed limitaon: Lower speed limit 0 vel. unit general I32 480000
/2
31
OP r
0x2946:003
(P340.03)
Speed limitaon: Upper speed limit source Maximum frequency [0] general U8 1 P -
0x2946:004
(P340.04)
Speed
limitaon: Lower speed limit source (-) Maximum frequency
[0]
general U8 1 P -
0x2946:005
(P340.05)
Speed limitaon: Upper frequency limit Device for 50-Hz mains:
50.0 Hz Device for 60-Hz
mains: 60.0 Hz
general I16 10 P -
0x2946:006
(P340.06)
Speed limitaon: Lower frequency limit Device for 50-Hz mains:
-50.0 Hz Device for 60-Hz
mains: -60.0 Hz
general I16 10 P -
0x2946:007
(P340.07)
Speed limitaon: Actual upper speed limit x.x Hz (Read only) general I16 10 - -
0x2946:008
(P340.08)
Speed limitaon: Actual lower speed limit x.x Hz (Read only) general I16 10 - -
0x2947:001 ...
0x2947:017
Inverter characterisc: Value y1 ... Value y17 0.00 V * MCTRL U16 100 P -
0x2948:001 Torque setpoint: Actual torque setpoint x.x % (Read only) general I16 10 - -
0x2948:002
(P336.02)
Torque setpoint: ramp me 1.0 s general U16 10 P -
0x2949:001
(P337.01)
Torque limit source selecon:
Posive torque limit
source
Max torque [0] general U8 1 P -
0x2949:002
(P337.02)
Torque limit source selecon: Negave torque limit
source
(-) Max torque [0] general U8 1 P -
0x2949:003
(P337.03)
Torque limit source selecon: Actual posive torque
limit
x.x % (Read only) general I16 10 - -
0x2949:004
(P337.04)
Torque limit source selecon: Actual negave
torque limit
x.x % (Read only) general I16 10 - -
0x29C0:001 Gain 59.68 A/Vs * MCTRL U32 100 P -
0x29C0:002 Reset me 45.5 ms * MCTRL U16 10 P -
0x29E0:001 Field weakening controller sengs: Gain (ASM) 0.000 Vs/V * MCTRL U32 1000 P -
0x29E0:002 Field weakening controller sengs: Reset me
(ASM)
1478.3 ms * MCTRL U32 10 P -
0x29E1 Field weakening controller Field limitaon 100.00 % MCTRL U16 100 OP r
* Default seng dependent on the model.
Appendix
P
arameter aribute list
322