Address Name Default seng Category Data type Factor A M
0x2911:005
(P450.05)
Frequency setpoint presets: Preset 5 0.0 Hz general U16 10 P -
0x2911:006
(P450.06)
Frequency setpoint presets: Preset 6 0.0 Hz general U16 10 P -
0x2911:007
(P450.07)
Frequency setpoint presets: Preset 7 0.0 Hz general U16 10 P -
0x2911:008
(P450.08)
Frequency setpoint presets: Preset 8 0.0 Hz general U16 10 P -
0x2911:009
(P450.09)
Frequency setpoint presets: Preset 9 0.0 Hz general U16 10 P -
0x2911:010
(P450.10)
Frequency setpoint presets: Preset 10 0.0 Hz general U16 10 P -
0x2911:011
(P450.11)
Frequency setpoint presets: Preset 11 0.0 Hz general U16 10 P -
0x2911:012
(P450.12)
Frequency setpoint presets: Preset 12 0.0 Hz general U16 10 P -
0x2911:013
(P450.13)
Frequency setpoint presets: Preset 13 0.0 Hz general U16 10 P -
0x2911:014
(P450.14)
Frequency setpoint presets: Preset 14 0.0 Hz general U16 10 P -
0x2911:015
(P450.15)
Frequency setpoint presets: Preset 15 0.0 Hz general U16 10 P -
0x2912:001
(P452.01)
Torque setpoint presets: Preset 1 100.0 % general I16 10 P -
0x2912:002
(P452.02)
Torque setpoint presets: Preset 2 100.0 % general I16 10 P -
0x2912:003
(P452.03)
Torque setpoint presets: Preset 3 100.0 % general I16 10 P -
0x2912:004
(P452.04)
Torque setpoint presets: Preset 4 100.0 % general I16 10 P -
0x2912:005
(P452.05)
Torque setpoint presets: Preset 5 100.0 % general I16 10 P -
0x2912:006
(P452.06)
Torque setpoint presets: Preset 6 100.0 % general I16 10 P -
0x2912:007
(P452.07)
Torque setpoint presets: Preset 7 100.0 % general I16 10 P -
0x2912:008
(P452.08)
Torque setpoint presets: Preset 8 100.0 % general I16 10 P -
0x2915
(P210.00)
Minimum frequency 0.0 Hz general U16 10 P -
0x2916
(P211.00)
Maximum frequency Device for 50-Hz mains:
50.0 Hz De
vice for 60-Hz
mains: 60.0 Hz
general U16 10 P -
0x2917
(P220.00)
Acceleraon me 1 5.0 s general U16 10 P rt
0x2918
(P221.00)
Deceleraon me 1 5.0 s general U16 10 P rt
0x2919
(P222.00)
Acceleraon me 2 5.0 s general U16 10 P -
0x291A
(P223.00)
Deceleraon
me 2 5.0 s general U16 10 P -
0x291B
(P224.00)
Auto-changeover threshold of ramp 2 0.0 Hz general U16 10 P -
0x291C
(P225.00)
Quick stop deceleraon me 1.0 s general U16 10 P -
0x291E:003
(P226.03)
Stop threshold 10.0 % general U16 10 P -
0x291F:001
(P317.01)
Skip frequencies: Skip frequency 1 0.0 Hz general U16 10 P -
* Default seng dependent on the model.
Appendix
P
arameter aribute list
321