Address Name Default seng Category Data type Factor A M
0x282B:007 Inverter diagnoscs: Default frequency setpoint x.x Hz (Read only) general I16 10 - -
0x282B:008 Inverter diagnoscs: Preset frequency setpoint x.x Hz (Read only) general I16 10 - -
0x282B:009 Inverter diagnoscs: Actual frequency setpoint x.x Hz (Read only) general I16 10 - -
0x282B:010 Inverter diagnoscs: Default PID setpoint x.xx PID unit (Read only) general I16 100 - -
0x282B:011 Inverter diagnoscs: Preset PID setpoint x.xx PID unit (Read only) general I16 100 - -
0x282B:012 Inverter diagnoscs: Default torque setpoint x.x % (Read only) general I16 10 - -
0x282B:013 Inverter diagnoscs: Preset torque setpoint x.x % (Read only) general I16 10 - -
0x2831 Inverter-Statuswort - (Read only) general U16 1 O t
0x2833 Inverter status word 2 - (Read only) general U16 1 O t
0x2838:001
(P203.01)
Start/stop conguraon: Start method Normal [0] general U8 1 PC -
0x2838:002
(P203.02)
Start/stop conguraon: Start at power-up O [0] general U8 1 P -
0x2838:003
(P203.03)
Start/stop conguraon: Stop method Standard ramp [1] general U8 1 P -
0x2839:002
(P760.02)
Fault conguraon: Restart delay 3.0 s general U16 10 P -
0x2839:003
(P760.03)
Fault conguraon: Number of restart aempts 5 general U8 1 P -
0x2839:004
(P760.04)
Fault conguraon: Trouble counter reset me 40.0 s general U16 10 P -
0x2839:005
(P760.05)
Fault conguraon: Trouble counter - (Read only) general U8 1 - -
0x2839:006 Fault conguraon: Fault handling in case of state
chang
e
Reset fault [0] general U8 1 P -
0x283A
(P304.00)
Limitaon of rotaon Both rotaonal
direcons
[1]
general U8 1 P -
0x2860:001
(P201.01)
Frequency control: Default setpoint source Analog input 1 [2] general U8 1 P -
0x2860:002
(P201.02)
PID control: Default setpoint source Keypad [1] general U8 1 P -
0x2860:003
(P201.03)
Torque control: Default setpoint source Analog input 1 [2] general U8 1 P -
0x2862
(P701.00)
Keypad setpoint increment 1 general U16 1 P -
0x2863
(P705.00)
Keypad language selecon English [1] general U8 1 P -
0x2864
(P703.00)
Keypad status display 0x00000000 general IDX 1 PH -
0x2900:001
(P332.01)
Speed controller sengs: Gain 0.00193 Nm/rpm * MCTRL U32 100000 P -
0x2900:002
(P332.02)
Speed controller sengs: Reset me 80.0 ms * MCTRL U16 10 P -
0x2904 Actual speed
lter me 2.0 ms MCTRL U16 10 P -
0x2910:001
(P335.01)
Inera
sengs: Motor moment of inera 3.70 kg cm² * MCTRL U32 100 P -
0x2910:002
(P335.02)
Inera
sengs: Load moment of inera 0.00 kg cm² MCTRL U32 100 P -
0x2910:003 Inera sengs: Coupling With backlash [2] MCTRL U8 1 P -
0x2911:001
(P450.01)
Frequency setpoint presets: Preset 1 20.0 Hz general U16 10 P -
0x2911:002
(P450.02)
Frequency setpoint presets: Preset 2 40.0 Hz general U16 10 P -
0x2911:003
(P450.03)
Frequency setpoint presets: Preset 3 Device for 50-Hz mains:
50.0 Hz Device for 60-Hz
mains: 60.0 Hz
general U16 10 P -
0x2911:004
(P450.04)
Frequency setpoint presets: Preset 4 0.0 Hz general U16 10 P -
* Default seng dependent on the model.
Appendix
P
arameter aribute list
320